- Self-consumption and feed-in to the grid
- Programmable supply priority for PV, Battery or Grid
- User-adjustable battery charging current suits different types of batteries
- Programmable multiple operations modes: Grid tie, Off grid, and grid-tie with backup
- Built-in Timer for various mode of on/off operation
- Multiple communication for USB, RS-232, Modbus and SNMP
- Monitoring software for real time status display and control
- Custom-made firmware by ODM contract
- Parallel operation up to 6 units.
- PHASE:3-phase in / 3-phase out
- MAXIMUM PV INPUT POWER: 14850 W
- RATED OUTPUT POWER: 10000 W
- MAXIMUM CHARGING POWER: 9600 W
GRID-TIE OPERATION
PV INPUT (DC)
- Nominal DC Voltage / Maximum DC Voltage: 720 VDC / 900 VDC
- Start-up Voltage / Initial Feeding Voltage: 320 VDC / 350 VDC
- MPP Voltage Range: 350 VDC ~ 850 VDC
- Number of MPP Trackers / Maximum Input Current: 2 / 2 x 18.6A
GRID OUTPUT (AC)
- Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
- Output Voltage Range: 184 – 264.5VAC per phase
- Nominal Output Current: 21.7A per phase
- Power Factor: > 0.99
EFFICIENCY
- Maximum Conversion Efficiency (DC/AC) 96% 95%
- European Efficiency@ Vnominal: 95%
OFF-GRID OPERATION
AC INPUT
- AC Start-up Voltage/Auto Restart Voltage: 120 – 140 VAC per phase
- Acceptable Input Voltage Range: 170 – 290 VAC per phase
- Maximum AC Input Current: 40 A
PV INPUT (DC)
- Maximum DC Voltage: 900 VDC
- MPP Voltage Range: 350 VDC ~ 850 VDC
- Number of MPP Trackers/Maximum Input Current: 2 / 2 x 18.6A
BATTERY MODE OUTPUT (AC)
- Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
- Output Waveform: Pure Sinewave
- Efficiency (DC to AC) 91%
HYBRID OPERATION
PV INPUT (DC)
- Nominal DC Voltage / Maximum DC Voltage: 720 VDC / 900 VDC
- Start-up Voltage / Initial Feeding Voltage: 320 VDC / 350 VDC
- MPP Voltage Range: 350 VDC ~ 850 VDC
- Number of MPP Trackers/Maximum Input Current: 2 / 2 x 18.6A
GRID OUTPUT (AC)
- Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
- Output Voltage Range: 184 – 265 VAC*per phase
- Nominal Output Current: 14.5 A per phase
AC INPUT
- AC Start-up Voltage / Auto Restart Voltage: 20 – 140 VAC per phase
- Acceptable Input Voltage Range: 170 – 290 VAC per phase
- Maximum AC Input Current: 40 A
BATTERY MODE OUTPUT (AC)
- Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
- Efficiency (DC to AC): 91%
BATTERY & CHARGER
- Nominal DC Voltage: 48 VDC
- Maximum Charging Current: Default 60A, 10A – 200A (Adjustable)
GENERAL
PHYSICAL
Dimension, D x W x H (mm) 167.2 x 500 x 622
Net Weight (kgs) 40
INTERFACE
Communication Port: RS-232/USB
Intelligent Slot: Optional SNMP, Modbus and AS-400 cards available