• Self-consumption and feed-in to the grid
  • Programmable supply priority for PV, Battery or Grid
  • User-adjustable battery charging current suits different types of batteries
  • Programmable multiple operations modes: Grid tie, Off grid, and grid-tie with backup
  • Built-in Timer for various mode of on/off operation
  • Multiple communication for USB, RS-232, Modbus and SNMP
  • Monitoring software for real time status display and control
  • Custom-made firmware by ODM contract
  • Parallel operation up to 6 units.
  • PHASE:3-phase in / 3-phase out
  • MAXIMUM PV INPUT POWER: 14850 W
  • RATED OUTPUT POWER: 10000 W
  • MAXIMUM CHARGING POWER: 9600 W

GRID-TIE OPERATION

PV INPUT (DC)

  • Nominal DC Voltage / Maximum DC Voltage: 720 VDC / 900 VDC
  • Start-up Voltage / Initial Feeding Voltage: 320 VDC / 350 VDC
  • MPP Voltage Range: 350 VDC ~ 850 VDC
  • Number of MPP Trackers / Maximum Input Current: 2 / 2 x 18.6A

GRID OUTPUT (AC)

  • Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
  • Output Voltage Range: 184 – 264.5VAC per phase
  • Nominal Output Current: 21.7A per phase
  • Power Factor: > 0.99

EFFICIENCY

  • Maximum Conversion Efficiency (DC/AC) 96% 95%
  • European Efficiency@ Vnominal: 95%

OFF-GRID OPERATION

AC INPUT

  • AC Start-up Voltage/Auto Restart Voltage: 120 – 140 VAC per phase
  • Acceptable Input Voltage Range: 170 – 290 VAC per phase
  • Maximum AC Input Current: 40 A

PV INPUT (DC)

  • Maximum DC Voltage: 900 VDC
  • MPP Voltage Range:     350 VDC ~ 850 VDC
  • Number of MPP Trackers/Maximum Input Current: 2 / 2 x 18.6A

BATTERY MODE OUTPUT (AC)

  • Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
  • Output Waveform:  Pure Sinewave
  • Efficiency (DC to AC) 91%

HYBRID OPERATION

PV INPUT (DC)

  • Nominal DC Voltage / Maximum DC Voltage: 720 VDC / 900 VDC
  • Start-up Voltage / Initial Feeding Voltage:      320 VDC / 350 VDC
  • MPP Voltage Range:                                      350 VDC ~ 850 VDC
  • Number of MPP Trackers/Maximum Input Current: 2 / 2 x 18.6A

GRID OUTPUT (AC)

  • Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
  • Output Voltage Range:   184 – 265 VAC*per phase
  • Nominal Output Current: 14.5 A per phase

AC INPUT

  • AC Start-up Voltage / Auto Restart Voltage: 20 – 140 VAC per phase
  • Acceptable Input Voltage Range: 170 – 290 VAC per phase
  • Maximum AC Input Current: 40 A

BATTERY MODE OUTPUT (AC)

  • Nominal Output Voltage: 230 VAC (P-N) / 400 VAC (P-P)
  • Efficiency (DC to AC): 91%

BATTERY & CHARGER

  • Nominal DC Voltage: 48 VDC
  • Maximum Charging Current: Default 60A, 10A – 200A (Adjustable)

GENERAL

PHYSICAL

Dimension, D x W x H (mm) 167.2 x 500 x 622

Net Weight (kgs) 40

INTERFACE

Communication Port: RS-232/USB

Intelligent Slot: Optional SNMP, Modbus and AS-400 cards available

 

 

 

 